gd真人


Closed UV disinfection series

Disinfection principle:

Modern UV C disinfection technology is based on optics, microbiology, chemistry, mechanics, electronics, fluid mechanics, aerodynamics and civil engineering and other disciplines on the basis of the use of specially designed high efficiency, high strength and long life C The band of ultraviolet light (T254nm) generated by the device produces strong ultraviolet light to irradiate water or air. When water or air in the bacterial virus through the UV C irradiation area, the ultraviolet light will penetrate the microbial cell membrane and nucleus, destruction of nucleic acid (DNA or RNA) molecular bonds, to lose its ability to copy or lose activity, because the cells can not be copied, The microbes will soon die, so that all bacteria and viruses are killed in the absence of any chemicals.


High efficiency: instantly kill a variety of bacteria, viruses and other pathogenic body. In the equipment rated disinfection of water within the range, according to different water quality, sterilization rate of 99% -99.99%.

High quality: the world's top high-quality dedicated UV C lamp, lamp life ≥ 12000 hours.

Good stability: the device can be 24 hours continuous, stable operation.

High reliability: the use of UV lamp UV C (T254nm) output utilization of more than 90%, higher reliability.

Practicality: used in drinking water, food processing water, swimming pool water, secondary water supply, water, municipal sewage and oil field water injection and other fields, disinfection will not change the water and food properties, primary colors, original flavor, does not produce any disinfection by-product.

Low cost: low operating costs, simple operation and maintenance, small size, no noise.

High security: equipment pressure 8Kg / cm ², protection class IP68, to ensure that the amount of UV leakage is 0, safe and reliable.


结构组成

Electronic control system: start and monitor the operation of UV C lamp. According to customer needs to configure a variety of advanced online monitoring instruments and remote control system.

Cleaning device: According to customer needs to configure the mechanical manual or automatic cleaning UV C lamp device.

Equipment installation: base fixed, directly connected in between the inlet and outlet pipes, the use of flange or threaded connection. The diameter and direction of the inlet and outlet pipes can be produced according to the user's requirements.


规格及技术参数

 

Water purification series specifications and technical parameters

model

specification

Tube tube diameter * length

(mm)

Treatment of water

(Ton / day)


Power consumption

(KW)

Cleaning method

Lamp type

Lamp life

NLC-50A

89*876

50

0.05

Manual / Auto

Low pressure

≥9000h

NLC-150A

108*876

150

0.10

Manual / Auto

Low pressure

≥9000h

NLC-200A

159*876

200

0.15

Manual / Auto

Low pressure

≥9000h

NLC-300A

159*876

300

0.20

Manual / Auto

Low pressure

≥9000h

NLC-360A

159*876

360

0.25

Manual / Auto

Low pressure

≥9000h

NLC-500A

219*876

500

0.30

Manual / Auto

Low pressure

≥9000h

NLC-600A

219*876

600

0.35

Manual / Auto

Low pressure

≥9000h

NLC-700A

219*876

700

0.40

Manual / Auto

Low pressure

≥9000h

NLC-1000A

219*876

1000

0.45

Manual / Auto

Low pressure

≥9000h

NLC-1500A

273*1580

1500

0.50

Manual / Auto

Low pressure

≥9000h

NLC-2000A

273*1580

2000

0.70

Manual / Auto

Low pressure

≥9000h

NLC-2500A

273*1580

2500

0.90

Manual / Auto

Low pressure

≥9000h

NLC-3000A

273*1580

3000

2.00

Manual / Auto

Low pressure high strength

≥12000h

NLC-4000A

325*1580

4000

2.40

Manual / Auto

Low pressure high strength

≥12000h

NLC-5000A

377*1580

5000

3.20

Manual / Auto

Low pressure high strength

≥12000h

NLC-7000A

480*1580

7000

4.80

Manual / Auto

Low pressure high strength

≥12000h

 


Hospital sewage series specifications and technical parameters

model

specification

Tube tube diameter * length

(mm)


Treatment of water

(Ton / day)


Power consumption

(KW)

Cleaning method

Lamp type

Lamp life

NLC-120H

133*1580

120

0.45

pneumatic

Low pressure

≥9000h

NLC-240H

133*1580

240

1.20

pneumatic

Low pressure high strength

≥12000h

NLC-360H

133*1580

360

1.60

pneumatic

Low pressure high strength

≥12000h

NLC-480H

159*1580

480

2.00

pneumatic

Low pressure high strength

≥12000h

NLC-600H

159*1580

600

2.40

pneumatic

Low pressure high strength

≥12000h

NLC-720H

219*1580

720

3.20

pneumatic

Low pressure high strength

≥12000h

NLC-960H

219*1580

960

4.00

pneumatic

Low pressure high strength

≥12000h

NLC-1200H

273*1580

1200

4.80

pneumatic

Low pressure high strength

≥12000h

NLC-1500H

273*1580

1500

6.40

pneumatic

Low pressure high strength

≥12000h

NLC-2000H

325*1580

2000

8.40

pneumatic

Low pressure high strength

≥12000h

NLC-2400H

325*1580

2400

9.60

pneumatic

Low pressure high strength

≥12000h

 

 

Water reuse series specifications and technical parameters

model

specification

Tube tube diameter * length

(mm)

Treatment of water

(Ton / day)


Power consumption

(KW)

Cleaning method

Lamp type

Lamp life

NLC-240Z

133*1580

240

1.20

pneumatic

Low pressure high strength

≥12000h

NLC-480Z

159*1580

480

2.40

pneumatic

Low pressure high strength

≥12000h

NLC-720Z

219*1580

720

3.60

pneumatic

Low pressure high strength

≥12000h

NLC-960Z

273*1580

960

4.80

pneumatic

Low pressure high strength

≥12000h

NLC-1200Z

273*1580

1200

6.00

pneumatic

Low pressure high strength

≥12000h

NLC-1500Z

273*1580

1500

7.20

pneumatic

Low pressure high strength

≥12000h

NLC-2000Z

325*1580

2000

9.60

pneumatic

Low pressure high strength

≥12000h

NLC-2400Z

325*1580

2400

11.20

pneumatic

Low pressure high strength

≥12000h