The function of the inverter is to convert the sine wave voltage of fixed voltage and frequency value from the grid into a rectangular wave voltage with fixed amplitude, variable frequency and variable pulse density, and then supply DBD type ozone generating device.
Frequency converter architecture is divided into: three-phase input single-phase output of the inverter (including NLOPS-11kW, NLOPS-22kW, NLOPS-37kW, NLOPS-55kW, NLOPS-90kW) basic architecture as shown in Figure 1-3a; The basic architecture of the output inverter (including NLOPS-110kW, NLOPS-225kW) is shown in Figure 1-3b.
Three-phase input single-phase output of the basic structure of the inverter | NLOPS-11kW、NLOPS-22kW、NLOPS-37kW、NLOPS-55kW、NLOPS-90kW |
picture 1-3a | |
Six-phase input three-phase output of the basic structure of the inverter | NLOPS-110kW、NLOPS-220kW |
picture 1-3b |
Model | Frequency input phase number | High frequency output phase number | rated power |
NLOPS-11kW | Three phases | Simplex | 11KW |
NLOPS-22kW | Three phases | Simplex | 22KW |
NLOPS-37kW | Three phases | Simplex | 37kW |
NLOPS-55kW | Three phases | Simplex | 55kW |
NLOPS-90kW | Three phases | Simplex | 90kW |
NLOPS-110kW | Six-phase | Three phases | 110kW |
NLOPS-225kW | Six-phase | Three phases | 225kW |